misc: ele_mu: Clear RR when initialize MU
When OS is doing ELE API call, before OS get the response, OS is force reseted, then it is possible that MU RR has data during initialization in SPL stage. So clear the RR registers, otherwise SPL ELE API call will work abnormal. Cc: Alice Guo <alice.guo@nxp.com> Cc: Marek Vasut <marex@denx.de> Signed-off-by: Peng Fan <peng.fan@nxp.com>
This commit is contained in:
@@ -25,9 +25,20 @@ struct imx8ulp_mu {
|
||||
void mu_hal_init(ulong base)
|
||||
{
|
||||
struct mu_type *mu_base = (struct mu_type *)base;
|
||||
u32 rr_num = (readl(&mu_base->par) & 0xFF00) >> 8;
|
||||
int i;
|
||||
|
||||
writel(0, &mu_base->tcr);
|
||||
writel(0, &mu_base->rcr);
|
||||
|
||||
while (true) {
|
||||
/* If there is pending RX data, clear them by read them out */
|
||||
if (!(readl(&mu_base->sr) & BIT(6)))
|
||||
return;
|
||||
|
||||
for (i = 0; i < rr_num; i++)
|
||||
readl(&mu_base->rr[i]);
|
||||
}
|
||||
}
|
||||
|
||||
int mu_hal_sendmsg(ulong base, u32 reg_index, u32 msg)
|
||||
|
||||
Reference in New Issue
Block a user